adverstisement



COURTAULDS AEROSPACE, INC -- PR1750 B-1/2 (1750B10) ACCELERATOR -- 8030-00-348-7888
=====================  Product Identification  =====================

Product ID:PR1750 B-1/2 (1750B10) ACCELERATOR
MSDS Date:10/21/1993
FSC:8030
NIIN:00-348-7888
Kit Part:Y
MSDS Number: BYXST
=== Responsible Party ===
Company Name:COURTAULDS AEROSPACE, INC
Address:5430 SAN FERNANDO RD.
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Country:US
Info Phone Num:818-240-2060
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:83574
=== Contractor Identification ===
Company Name:PRC-DESOTO INTERNATIONAL, INC. A PPG INDUSTRIES COMPANY
Address:5430 SAN FERNANDO RD
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Country:US
Phone:818-240-2060
CAGE:83574

=============  Composition/Information on Ingredients  =============

Ingred Name:HYDROGENATED TERPHENYL (VP = 1 MMHG)
CAS:61788-32-7
RTECS #:WZ6535000
Fraction by Wt: 30%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.5 PPM
ACGIH TLV:0.5 PPM

Ingred Name:DIPHENYL GUANIDINE (GUANIDINE,N,N',DIPHENYL)
CAS:102-06-7
Fraction by Wt: <5.0%
Other REC Limits:NONE RECOMMENDED

Ingred Name:MANGANESE DIOXIDE (SARA 313)
CAS:1313-13-9
RTECS #:OP0350000
Fraction by Wt: 55.0%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (CEILING)
ACGIH TLV:5 MG/M3 (AS MN)

Ingred Name:CARBON BLACK (AIRBORNE CONTAMINANT, FULLY ENCAPSULATED)
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: 5.0%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYES: SEVERELY IRRITATING. SKIN:
    IRRIT. TOXIC BY ABSORPTION MAY BE SENSITIZER. INHAL: POSSIBLE
    DIZZINESS, IRRITATION, DROWSINESS, FATIGUE, MANGANESE PNEUMONITIS.
    MANGANESE POISONING POSSIBLE BUT UNLIK ELY. INGESTION: TOXIC ON
    ORAL CONSUMPTION. BASED ON INCONCLUSIVE STUDIES, REPRODUCTIVE
    EFFECTS HAVE BEEN REPORTED.
Effects of Overexposure:INGESTION: APATHY, INSOMNIA, WEAKNESS IN LEGS,
    MUSCULAR TWITCHING, EMOTIONAL DISTRESS.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/LUKE WARM WATER 15 MINUTES. IF SYMPTOMS PERSIST
    CONSULT DR. SKIN: WASH W/SOAP & WATER. IF SYMPTOMS PERSIST CONSULT
    DR. INHALATION: GET FRESH AIR. IF SYMPTOMS PRESENT CONSULT DR.
    INGESTIO N: CONSULT DR.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:315F,157C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER.
Fire Fighting Procedures:USE AIR SUPPLIED RESPIRATOR. USE WATER TO COOL
    HEAT EXOPSED CONTAINERS.
Unusual Fire/Explosion Hazard:EXCESSIVE HEAT MAY CAUSE DECOMP OF
    MANGANESE DIOXIDE, RESULTING IN OXIDATION & POSSIBLE IGNITION OF
    HYDROCARBON.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SCOOP INTO CONTAINERS. CLEAN UP RESIDUE
    W/SUITABLE SOLVENT.

======================	Handling and Storage  ======================

Handling and Storage Precautions:WASH THOROUGHLY AFTER HANDLING &
    BEFORE SMOKING OR EATING. AVOID INGESTION.
Other Precautions:NONE

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT REQUIRED
Ventilation:GENERAL
Protective Gloves:SOLVENT RESISTANT
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE
Supplemental Safety and Health
NK

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:644F,340C
Spec Gravity:1.97
Evaporation Rate & Reference:NONVOLATILE
Appearance and Odor:BLACK PASTE
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
EASILY OXIDIZABLE MATERIALS
Hazardous Decomposition Products:OXIDES OF CARBON & NITROGEN, MANGANESE
    COMPOUNDS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:NOT HAZARDOUS WASTE PER EPA REGS. DISPOSE IN
    ACCORDANCE W/FEDERAL, STATE, LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.