adverstisement



HY-TEST 303 CORP (THRU PARKWAY FABRICATORS) -- AQUAGLIDE SILICONE LUBRICANT -- 4220-00-516-3389
=====================  Product Identification  =====================

Product ID:AQUAGLIDE SILICONE LUBRICANT
MSDS Date:01/01/1985
FSC:4220
NIIN:00-516-3389
MSDS Number: BFCHM
=== Responsible Party ===
Company Name:HY-TEST 303 CORP (THRU PARKWAY FABRICATORS)
Emergency Phone Num:201-933-0300
CAGE:OO156
=== Contractor Identification ===
Company Name:HY-TEST 303 CORP (THRU PARKWAY FABRICATORS)
Address:9 MEADOW RD
Box:City:RUTHERFORD
Phone:201-933-0300
CAGE:OO156

=============  Composition/Information on Ingredients  =============

Ingred Name:PETROLEUM DISTILLATES (NAPHTHA OR RUBBER SOLVENT)
CAS:8002-05-9
RTECS #:SE7449000
Fraction by Wt: 30%
OSHA PEL:400 PPM
ACGIH TLV:400 PPM; 8990

Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE)  (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 45%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:350 PPM
ACGIH TLV:350 PPM/450STEL;9394
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:ISOBUTANE
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 10%
ACGIH TLV:1000 PPM

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 10%
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9192

=====================  Hazards Identification  =====================

Effects of Overexposure:INHAL:ANESTHETIC.IRRITATES
    RESPIR.TRACT,HEADACHE,DIZZINESS,CONFUSION;SKIN/EYE:PRIMARY
    IRRITATION

=======================  First Aid Measures  =======================

First Aid:INHAL:MOVE TO FRESH AIR.RESTORE BREATHING.KEEP WARM &
    QUIET.CALL DR. EYES:FLUSH IMMEDIATELY W/LARGE AMTS OF RUNNING WATER
    FOR 15 MIN.MINIM. CALL DR. SPRAY:WIPE OFF WITH TOWEL.REMOVE
    REMAINDER W/MINERA L SPIRITS.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE NFPA CL-B EXTIN.CO*2,DRY CHEM.OR FOAM.
Fire Fighting Procedures:CANS WILL RUPTURE FROM INTERN.PRESS.AT ABOUT
    190 F.
Unusual Fire/Explosion Hazard:WATER SPRAY MAYBE INEFFECTIVE.WEAR
    GOGGLES & SELF-CONTA BREATHG APPARATUS.USE WATER TO COOL CONTAINE

==================  Accidental Release Measures  ==================

Spill Release Procedures:MOVE ALL SOURCES OF IGNITION.AVOID BREATHING
    VAPORS.VENTILATE AREA.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE ABOVE 120F.STORE LARGE
    AMTS IN BLDG.DESIGNED & PROTECTED FOR STORAGE OF NFPA CLASS IA
    FLAMMABLE LIQUIDS.
Other Precautions:DONOT SPRAY IN EYES.DONOT PUNCTURE OR INCINERATE
    CANS.DONOT STICK PIN,NAIL,OR ANY OTHER SHARP OBJECTS INTO OPENING
    INTO OPENING ON TOP OF CAN.DONOT TAKE INTERNALLY.DONOT
    FLAMECUT,BRAZE,OR WELD

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:OUTDOOR/OPEN AREA:B OF M.APPRV
    MECHAN.RESPIR.;INDOOR:CHEM-MECH.TY
Ventilation:GEN.DILUTION OF LOCAL EXHAUST TO MAINTAIN BELOW TLV.
Protective Gloves:NONE
Eye Protection:NO SPEC.PROTECT.REQUIRE
Other Protective Equipment:PREVENT PROLONGED SKIN CONTACT TO
    CONTAMINATED CLOTHING.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:G3
Vapor Density:>1.
Evaporation Rate & Reference:(ETHER=1) <1 (SOLV
Percent Volatiles by Volume:98 %

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS
Stability Condition to Avoid:AVOID STORAGE ABOVE 120F. AVOID DROPPING
    CANS
Hazardous Decomposition Products:CARBON MONOXIDE,PHOSGENE,AND OTHER
    TOXIC FUMES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IAW LOCAL,STATE AND FED.REGUL.INCINERATE
    IN APPROVED FACILITY. DONOT INCINERATE CLOSED CONTAINER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.