adverstisement



TECHNOLUBE PRODUCTS CO -- MIL-F-1711B POWER TRANSMISSION FLUID -- 9150-00-261-8317
=====================  Product Identification  =====================

Product ID:MIL-F-1711B POWER TRANSMISSION FLUID
MSDS Date:04/23/1996
FSC:9150
NIIN:00-261-8317
MSDS Number: BRPCL
=== Responsible Party ===
Company Name:TECHNOLUBE PRODUCTS CO
Address:5814 E 61ST ST
City:LOS ANGELES
State:CA
ZIP:90040-3412
Country:US
Info Phone Num:213-727-7792
Emergency Phone Num:213-727-7792
Preparer's Name:RICHARD J. EBERHARDT
CAGE:8Y842
=== Contractor Identification ===
Company Name:LUBRICATING SPECIALTIES CO. TECHNOLUBE PRODUCTS DIV
Address:3365 E. SLAUSON AVE
Box:City:LOS ANGELES
State:CA
ZIP:90058
Country:US
Phone:562-776-4033; FAX:562-776-4003
CAGE:8Y842
Company Name:NAUGHTON ENERGY CORP
Address:RT 940
Box:709
City:POCONO PINES
State:PA
ZIP:18350-0709
Country:US
Phone:570-646-0422
CAGE:1DL10
Company Name:TECHNOLUBE PRODUCT COMPANY
Address:8015 PARAMOUNT BLVD.
Box:City:PICO RIVERA
State:CA
ZIP:90660-4811
Country:US
Phone:562 776-4000 GEN: 562-776-4000
CAGE:2X769

=============  Composition/Information on Ingredients  =============

Ingred Name:HYDROTREATED MIDDLE PETROLEUM DISTILLATE
CAS:64742-46-7
RTECS #:JN9379645
Fraction by Wt: <85%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Ingred Name:NON HAZARDOUS INGREDIENTS
Fraction by Wt: >15%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION: NOT NORMALLY
    EXPECTED TO CAUSE ANY ILL EFFECTS. INHALATION: NO SIGNIFICANT
    ADVERSE HEALTH EFFECTS ARE EXPECTED FOR SHORT TERM EXPOSURE. EYE:
    NOT NORMALLY EXPECTED TO CAUSE ANY ILL EF FECTS. SKIN: NOT NORMALLY
    EXPECTED TO CAUSE ANY ILL EFFECTS. CHRONIC: PROLONGED/REPEATED
    CONTACT MAY CAUSE IRRITATION.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
    CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:MILD SKIN IRRITATION AND INFLAMMATION.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE AN PRE-EXISTING SKIN
    DISORDERS.

=======================  First Aid Measures  =======================

First Aid:SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH SOAP AND WATER.
    GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INHALATION: REMOVE TO
    FRESH AIR & RESTORE BREATHING IF NECESSARY. GET MEDICAL ATTENTION.
    EYE : IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING
    EYELIDS OPEN. GET MEDICAL ATTENTION. INGESTION: GET IMMEDIATE
    MEDICAL ATTENTION. DO NOT INDUCE VOMITING. NOTHING BY MOUTH IF
    UNCONSCIOUS.

=====================  Fire Fighting Measures  =====================

Flash Point:>209F,>98C
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
    CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
    FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
    CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
    HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. AVOID BREATHING VAPOR. USE
    SELF-CONTAINED BREATHING APPARATUS. STOP FLOW. WIPE OR MOP UP OR
    ABSORB WITH DIATOMACEOUS EARTH OR OTHER INERT MATERIAL. STORE IN
    APPROPRIATE CONTAINER FOR D ISPOSAL. AVOID CONTACT WITH SKIN, EYES
    OR CLOTHING

======================	Handling and Storage  ======================

Handling and Storage Precautions:MINIMUM FEASIBLE HANDLING TEMPERATURES
    SHOULD BE MAINTAINED. PERIODS OF EXPOSURE TO HIGH TEMPERATURES
    SHOULD BE MINIMIZED. AVOID WATER CONTAMINATION.
Other Precautions:MISUSE OF EMPTY CONTAINERS CAN BE HAZARDOUS. EMPTY
    CONTAINERS CAN BE HAZARDOUS IF USED TO STORE TOXIC, FLAMMABLE, OR
    REACTIVE MATERIALS. CUTTING OR WELDING OF EMPTY CONTAINERS MIGHT
    CAUSE FIRE, EXPLOS ION OR TOXIC FUMES FROM RESIDUES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:AIRBORNE CONCENTRATIONS SHOULD BE KEPT TO LOWEST
    LEVELS POSSIBLE. IF VAPOR, MIST OR DUST IS GENERATED, USE
    RESPIRATOR APPROVED BY NIOSH AS APPROPRIATE. SUPPLIED AIR
    RESPIRATORY PROTECTION SHOULD BE US ED FOR CLEANING LARGE SPILLS OR
    TANKS.
Ventilation:PROVIDE ADEQUATE VENTILATION TO MEET COMPONENT OCCUPATIONAL
    EXPOSURE LIMITS.
Protective Gloves:RECOMMENDED
Eye Protection:USE CHEMICAL SAFETY GOGGLES
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER. CHEMICALLY
    RESISTANT BOOTS AND APRONS RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
    EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE
    REUSE.
Supplemental Safety and Health
DISCARD CONTAMINATED LEATHER GLOVES AND SHOES.

==================  Physical/Chemical Properties  ==================

HCC:V6
Boiling Pt:B.P. Text:>392F,>200C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:<0.01 MMHG
Vapor Density:>1 (AIR=1)
Spec Gravity:0.86 (WATER=1)
Evaporation Rate & Reference:<1 (ETHER = 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW, OILY LIQUID, PETROLEUM ODOR
Percent Volatiles by Volume:NIL

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
    OF IGNITION. CONTACT WITH STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:CARBON MONOXIDE AND ASPHYXIANTS

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF WASTE IN ACCORDANCE WITH LOCAL, STATE
    AND FEDERAL REGULATIONS

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.