adverstisement



NEUTRON INDUSTRIES INC -- DOWN N DIRTY AEROSOL -- 7930-00F038344
=====================  Product Identification  =====================

Product ID:DOWN N DIRTY AEROSOL
MSDS Date:02/01/1994
FSC:7930
NIIN:00F038344
MSDS Number: BWTTN
=== Responsible Party ===
Company Name:NEUTRON INDUSTRIES INC
Address:7107 N BACK CANYON HWY
City:PHOENIX
State:AZ
ZIP:85021-7619
Country:US
Info Phone Num:800-421-8481/216-861-7114
Emergency Phone Num:800-421-8481/216-861-7114
CAGE:GO248
=== Contractor Identification ===
Company Name:NETRON INDUSTRIES INC
Address:7107 N BACK CANYON HWY
Box:City:PHOENIX
State:AZ
ZIP:85021-7619
Country:US
Phone:800-421-8481
CAGE:0FVJ0
Company Name:NEUTRON INDUSTRIES INC
Address:7107 N BACK CANYON HWY
City:PHOENIX
State:AZ
ZIP:85021-7619
Country:US
Phone:800-421-8481
CAGE:GO248

=============  Composition/Information on Ingredients  =============

Ingred Name:2-BUTOXYETHANOL (ETHYLENE GLYCOL MONOBUTYL ETHER), BUTYL
    CELLOSOLVE, BUTYL GLYCOL, GLYCOL ETHER EB
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: <5%
Other REC Limits:25 PPM (SKIN)
OSHA PEL:50 PPM (SKIN)
ACGIH TLV:25 PPM (SKIN)

Ingred Name:ISOBUTANE, 2-METHYLPROPANE
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: <5%
Other REC Limits:1000 PPM
OSHA PEL:1800 MG/CUM
ACGIH TLV:1000 PPM

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: <5%
Other REC Limits:1800 MG/CUM
OSHA PEL:1000 PPM
ACGIH TLV:SIMPLE ASPHYXIANT

Ingred Name:AMMONIUM HYDROXIDE, AQUA AMMONIA
CAS:1336-21-6
RTECS #:BQ9625000
Fraction by Wt: <1%
Other REC Limits:25 PPM
ACGIH TLV:25 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:DIRECT CONTAACT CAN CAUSE EYE
    IRRITATION. 2-BUTOXYETHANOL: MAY CAUSE BLOOD CELL ABNORMALITIES.
    CHRONIC EXPOSURE MAY CAUSE LUNG, LIVER, KIDNEY/CNS DAMAGE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION. HYDROCARBON PROPELLANT-DIZZINESS,
    HEADACHE
Medical Cond Aggravated by Exposure:HEART DISEASE, RESPIRATORY
    DISORDERS.

=======================  First Aid Measures  =======================

First Aid:INGESTION: DON'T INDUCE VOMITING. INHALATION: REMOVE TO FRESH
    AIR, GIVE OXYGEN. EYES: FLUSH IMMEDIATELY W/PLENTY OF COOL WATER
    FOR 15 MINS. SKIN: WASH W/SOAP & WATER. OBTAIN MEDICAL ATTENTION IN
    ALL C ASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:-40F PROPELLANT
Extinguishing Media:CO2, DRY CHEMICAL, WATER FOG
Fire Fighting Procedures:KEEP CONTAINERS COOL. USE SHIELDING TO PROTECT
    PERSONNEL FROM VENTING, RUPTURING/BURSTING CANS.
Unusual Fire/Explosion Hazard:EXPOSURE TO TEMP >120F MAY CAUSE CANS TO
    VENT, RUPTURE/BURST.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. WIPE UP W/RAGS/PAPER TOWELS.
    USE OIL ABSORBENT TO SOAK UP MATERIAL. PUT INTO CONTAINER. DISPOSE
    AS HAZARDOUS WASTE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTENTS UNDER PRESSURE. DON'T STORE
    CANS IN STRONG SUNLIGHT, NEAR FLAME, SPARKS/TEMP >120F. DON'T
    PUNCTURE/INCINERATE CANS.
Other Precautions:DON'T SMOKE WHILE USING. DON'T SPRAY INTO EYES/MOUTH.
    NOT FOR HOUSEHOLD/RESALE. KEEP OUT OF REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:TYPICALLY NOT REQUIRED WHEN SPRAYING > 1/2
    CONTINUOUSLY/ >1 CAN CONSECUTIVELY USE NIOSH APPROVED RESPIRATOR.
Ventilation:REQUIRED.
Protective Gloves:REQUIRED
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:LONG SLEEVES & LONG PANTS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-40 TO 212F
Spec Gravity:0.9
Solubility in Water:COMPLETE
Appearance and Odor:WHITE AERSOL FOAM SPRAY W/PEPPERMINT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:TEMP >120F.
Hazardous Decomposition Products:IN FIRE WILL DECOMPOSE TO CO2 & WATER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DON'T PUNCTURE/INCINERATE CANS. GIVE TO A
    DISPOSAL SERVICE EQUIPPED TO SAFETY HANDLE & DISPOSE/PRESSURIZED
    CONTAINERS. DISPOSE AS HAZARDOUS WASTE IAW/FEDERAL, STATE & LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.