HENRY W W CO -- SOLVENT FOR HENRY CARPET SEAM ADHESIVE, 244 -- 8040-00N026893
=====================  Product Identification  =====================

Product ID:SOLVENT FOR HENRY CARPET SEAM ADHESIVE, 244
MSDS Date:12/16/1991
FSC:8040
NIIN:00N026893
MSDS Number: BMDFN
=== Responsible Party ===
Company Name:HENRY W W CO
Address:5608 SOTO ST
City:HUNTINGTON PARK
State:CA
ZIP:90255-2629
Country:US
Info Phone Num:213-583-4961 / FAX 213-582-8451
Emergency Phone Num:213-583-4961
CAGE:11761
=== Contractor Identification ===
Company Name:HENRY W W CO
Box:3001
City:LANCASTER
State:PA
ZIP:17604
Country:US
Phone:717-396-2328;717-396-2935
CAGE:11761

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE). VP: 160
    @ 68F.
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 100%
OSHA PEL:350 PPM;450 PPM STEL
ACGIH TLV:350 PPM;450 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL OF HIGH CONC OF VAPS
    INTOXICATES, DEPRESSES NERV SYS & SUFFOCATES. RPTS HAVE ASSOC RPTD
    & PRLNGD OCCUP OVEREXP TO SOLV W/PERM BRAIN & NERV SYS DMG.
    INTENTIONAL MISUSE BY DELIB CONC & INHALING VA PS MAY BE
    HARMFUL/FATAL. NO LONG TERM LAB TESTS TO DETERMINE CHRONIC EFTS.
    SKIN IRRIT & DERMAT MAY DEV (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:FROM PRLNGD CONT W/SKIN. CHLOROCARBON
    MATLS HAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB
    ANIMALS & COULD HAVE A SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,
    EPINEPHRINE) MAY BE CO NTRAINDICATED EXCEPT FOR LIFE-SUSTAINING
    USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:HEART AILMENTS AND SKIN CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:INHAL: MOVE PERSON TO FRESH AIR AND APPLY ARTF RESP IF
    NEEDED. CALL MD IMMEDIATELY. EYE: FLUSH WITH PLENTY OF WATER FOR AT
    LEAST 15 MINUTES. INGEST: IF SWALLOWED, CONTACT POIS CTL CTR AND
    GET MD. SKIN : WASH THOROUGHLY WITH SOAP AND WATER OR HAND CLEANER.
    DOCTORS NOTE: DO NOT ADMINISTER EPINEPHRINE.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Lower Limits:NONE
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
    & FULL PROTECTIVE EQUIPMENT . GAS MASKS SHOULD BE AVAIL IF LARGE
    AREAS ARE INVOLVED.
Unusual Fire/Explosion Hazard:MINIMAL FIRE HAZ, BUT PROPER FRESH AIR
    VENT IS ESSENTIAL TO AVOID CONC OF TOX VAPS WHICH MAY ALSO GIVE
    SURF FLASH IF IN CONT W/PILOT LIGHTS, SPARKS (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:CLEAN UP SPILLS PROMPTLY, PROVIDING POSITIVE
    FRESH AIR VENT TO PERS. SCOOP MATL INTO DOT APPROVED CNTNR. REMOVE
    TO SAFE PLACE OUTDOORS WHERE MATL CAN DRY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN. USE
    ONLY AS DIRECTED ON LABEL. DO NOT TAKE INTERNALLY. CLOSE CNTNR
    AFTER EACH USE. DO NOT RE-USE CONTAINER.
Other Precautions:AVOID SKIN & EYE CONT. NO SMOKING IN AREA OF USE. DO
    NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT
    SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL
    AND/OR PHOSGENE (F P N).

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:PROPER VENTILATION NORMALLY SUFFICIENT. IF EYE
    WATERING, HEADACHES OR DIZZINESS ARE EXPERIENCED, INCREASE FRESH
    AIR SUPPLY. WEAR NIOSH/MSHA APPROVED RESPIRATORY EQUIPMENT, OR
    LEAVE THE AREA.
Ventilation:VAPS MAY CAUSE SURF FLASH FIRE. ADEQ VENT IS ESSENTIAL TO
    PVNT BUILD-UP OF VAPS. OPEN ALL WINDOWS & DOORS & (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE REQUIRED.
Work Hygienic Practices:WASH SKIN THOROUGHLY WITH SOAP AND WATER OR
    HAND CLEANER.
Supplemental Safety and Health
EXPLO HAZ: OR OTHER FLAMES. THERM DECOMP PRODS MAY INCLUDE HCL &
    PHOSGENE . VENT: UTILIZE OTHER MEANS TO ASSURE FRESH AIR ENTRY AND
    EXHAUST DURING USE AND UNTIL ALL VAPORS ARE GONE. A SOLVENT OD OR
    MAY BE NOTED UNTIL PRODUCT DRIES.

==================  Physical/Chemical Properties  ==================

HCC:T4
Boiling Pt:B.P. Text:163F,73C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.29 
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIS SUCH AS LYE AND TSP, AND ALUMINUM.
Stability Condition to Avoid:DO NOT PERMIT VAPORS TO PASS THROUGH OPEN
    FLAME.
Hazardous Decomposition Products:IN A FIRE, HYDROGEN CHLORIDE AND
    NOXIOUS GASES. PHOSGENE .

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
    LOCAL DISPOSAL REGULATIONS. DO NOT FLUSH SOLVENT DOWN DRAINS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.