GE CO OUTDOOR BREAKER BUSINESS SECT -- 19F142XB/19F500 -- 5910-00-922-8374
=====================  Product Identification  =====================

Product ID:19F142XB/19F500
MSDS Date:01/01/1985
FSC:5910
NIIN:00-922-8374
MSDS Number: BFWPG
=== Responsible Party ===
Company Name:GE CO OUTDOOR BREAKER BUSINESS SECT
Address:6901 ELMWOOD AVE
City:PHILADELPHIA
State:PA
ZIP:19142-1815
Country:US
Emergency Phone Num:NONE
CAGE:MO239
=== Contractor Identification ===
Company Name:GE CO OUTDOOR BREAKER BUSINESS SECT
Address:6901 ELMWOOD AVE
Box:City:PHILADELPHIA
State:PA
ZIP:19142-1815
Country:US
CAGE:MO239
Company Name:GENERAL ELECTRIC OUTDOOR BREAKER BUSINESS SECTION
Address:6901 ELMWOOD AVE
Box:City:PHILADELPHIA
State:PA
ZIP:19142-1815
Country:US
Phone:215-726-2626
CAGE:03497

=============  Composition/Information on Ingredients  =============

Ingred Name:POLYCHLORINATED BIPHENYLS (PCBS)  (SARA III)
CAS:1336-36-3
RTECS #:TQ1350000
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

=====================  Hazards Identification  =====================

Effects of Overexposure:INHAL: RESP TK IRRIT;
    SKIN/EYE;IRRIT,INFLAM,CHLROACNE; MAY CAUSE LIVER DAMAGE.

=======================  First Aid Measures  =======================

First Aid:INHAL: RMV TO FRESH AIR. IF NOT BRTHNG,GIVE CPR, IF BRTHNG
    DIFF,GIVE OXYGEN. EYE:IMMED FLUSH W/PLENTY OF WATER. SKIN:WASH
    W/SOAP&WATER. RMV CONTAM CLTHNG&SHOES. INGEST:INDUCE VOMIT. RPT
    UNTIL VOMIT IS  CLEAR. NOTHG BY MOUTH IF UNCONSC. GET MEDICAL ATT

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:EXTINQUISH W. AGENT SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR CHEMICAL PROTECTIVE SUIT WITH SELF CONTD
    BRTHG APP.
Unusual Fire/Explosion Hazard:MATL IS NON-FLAMMABLE BUT MAY GENERATE
    TOXIC GASES IN HEAT OF FIRE

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVAC NON-ESSENTL PERSONNEL. VENT SPIL AREA.
    WEAR PROTECT EQUIPT. STOP LEAK. SOAK UP LIQUID W/NON-REACTIVE MATL
    (SAND, DIRT, ETC) OR RMV BY DIKE & PUMPING OR OTHER SUITABLE MEANS.
    CLEAN AREA W/SUITABLE  SAFETY SOLVENT. LAUNDER CONTAMINATED CLTHG.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL,DRY,WELL VENTILATED
    AREA. PROTECT FROM PHYSICAL DAMAGE.AVOID ANY PHYSICAL CONTACT. KEEP
    CONTAINERS TIGHTLY CLOSED
Other Precautions:CHLORODIPHENYLS MAY ATTACK SOME TYPES OF RUBBER AND
    PLASTIC. DO NOT USE CONTAMINATED WORK CLOTHING. WASH/SHOWER AFTER
    EXPOSURE TO PCB'S.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MESA APPR SCBA/AIR SUPP RESPIR.
Ventilation:LOCAL EXHAUST TO MAINTN BELOW TLV.
Protective Gloves:IMPERVIOUS
Eye Protection:GOGGLES/FACE SHIELD
Other Protective Equipment:WEAR FULL PROTECTIVE CLOTHING.
Supplemental Safety and Health
OVEREXPOS:CAN CAUSE FORMATION OF CYSTS.CAUSES STILLBIRTHS.IRRITATES
    EYES,NOSE,THROAT.

==================  Physical/Chemical Properties  ==================

HCC:Z3
Solubility in Water:NEGLIGIBLE
Appearance and Odor:PALE YELLOW VISCOUS LIQUID W/HYDROCARBON ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:SEE OTHER PRECAUTIONS
Hazardous Decomposition Products:HYDROGEN CHLORIDE, CO, & OTHER
    TOXIC/IRRITATING GASES/FUMES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTROLLED DISPOSAL REQD. GEN. V.HIGH TEMP
    INCINERATION. IAW ALL LOCAL, STATE, & FEDERAL REGULATIONS.
    PERMITTED DISPOSAL OPERATOR REQUIRED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their