EXXON COMPANY,U.S.A. -- UNIVOLT INSULATING OILS ANSI/ASTM D3487 TYPE I OR II -- 6685-00-553-8731
=====================  Product Identification  =====================

Product ID:UNIVOLT INSULATING OILS ANSI/ASTM D3487 TYPE I OR II
MSDS Date:06/01/1989
FSC:6685
NIIN:00-553-8731
MSDS Number: BXCNX
=== Responsible Party ===
Company Name:EXXON COMPANY,U.S.A.
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Info Phone Num:713-656-3424
Emergency Phone Num:713-656-3424
CAGE:EO384
=== Contractor Identification ===
Company Name:EXXON COMPANY U.S.A.
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-656-5949 / 713-656-3424
CAGE:29700
Company Name:EXXON COMPANY,U.S.A.
Address:800 BELL ST
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-870-6000
CAGE:EO384
Company Name:VANTRAN ELECTRIC
Box:UNKNOW
CAGE:25050

=============  Composition/Information on Ingredients  =============

Ingred Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RATS) > 5 G/KG
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:PROLONGED OR REPEATED SKIN CONTACT MAY
    CAUSE SKIN IRRITATION.  PROLONGED OR REPEATED CONTACT TENDS TO
    REMOVE SKIN OILS, POSSIBLY LEADING TO IRRITATION AND DERMATITIS.
    EYE CONTACT MAY CAUSE IRRITATION.  ASPIRATION HAZARD.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
    CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
    CARCINOGENS.
Effects of Overexposure:SKIN IRRITATION, DERMATITIS, EYE IRRITATION,
    CHEMICAL PNEUMONIA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
    OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
    WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
    ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
    MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. IF OCCURS,
    KEEP HEAD BELOW HIPS. GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:293F,145C
Autoignition Temp:Autoignition Temp Text:>400F
Lower Limits:0.9 %
Upper Limits:7 %
Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEMICAL, CARBON
    DIOXIDE AND VAPORIZING LIQUID TYPE EXTINGUISHING AGENTS.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING, INCLUDING
    HELMET, SELF-CONTAINED BREATHING APPARATUS, WHEN FIGHTING A
    CHEMICAL FIRE. USE WATER SPRAY TO KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:FIRE MAY PRODUCE HAZARDOUS AND/OR TOXIC
    DECOMPOSITION PRODUCTS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:RECOVER FREE PRODUCT. ADD SAND, EARTH OR OTHER
    SUITABLE ABSORBENT MATERIAL TO SPILL AREA. MINIMIZE SKIN CONTACT.
    KEEP PRODUCT OUT OF SEWERS AND WATERCOURSES. ADVISE SUTHORITIES IF
    PRODUCT HAS ENTERED  SEWERS OR WATERCOURSES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
    USE. DO NOT STORE NEAR HEAT, SPARKS, FLAME OR STRONG OXIDANTS.
    MINIMIZE BREATHING VAPOR, MIST OR FUMES.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN. REMOVE
    AND LAUNDER CONTAMINATED CLOTHING BEFORE RE-USE. REMOVE
    CONTAMINATED SHOES AND THOROUGHLY CLEAN; DISCARD IF OIL SOAKED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE SUPPLIED-AIR RESPIRATORY PROTECTION IN
    CONFINED OR ENCLOSED SPACES IF NEEDED.
Ventilation:USE LOCAL EXHAUST TO CAPTURE VAPOR, MISTS OR FUMES, IF
    NECESSARY. PROVIDE VENTILATION SUFFICIENT TO MAINTAIN TLVS.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:SPLASH GOGGLES OR FACE SHIELD
Other Protective Equipment:USE CHEMICAL-RESISTANT APRON OR OTHER
    IMPERVIOUS CLOTHING IF NEEDED TO AVOID CONTAMINATING REGULAR
    CLOTHING.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
    BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
NON-PCB OIL CONTAINED IN COMPOUND-PRESSURE GAGE. EMPTY CONTAINERS
    RETAIN RESIDUE AND CAN BE DANGEROUS. DO NOT PRESSURIZE, CUT, WELD,
    BRAZE, SOLDER, DRILL, GRIND OR EXPOSE SUCH CONTAINERS TO HEAT, FLAM
    E, SPARKS, STATIC ELECTRICITY OR OTHER SOURCES OF IGNITION. THEY
    MAY EXPLODE AND CAUSE INJURY OR DEATH.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:460F,238C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:< 0.01
Vapor Density:NOT GIVEN
Spec Gravity:0.873
pH:7
Evaporation Rate & Reference:< 0.01 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR WATER-WHITE LIQUID WITH FAINT PETROLEUM
    HYDROCARBON ODOR
Percent Volatiles by Volume:NIL

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
LIQUID CHLORINE, CONCENTRATED OXYGEN, SODIUM HYPOCHLORITE OR CALCIUM
    HYPOCHLORITE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES, SMOKE, CARBON MONOXIDE, SULFUR
    OXIDES, ALDEHYDES AND OTHER DECOMPOSITION PRODUCTS IN CASE OF
    INCOMPLETE BURNING.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
    ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
    LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.