adverstisement



CLIFTON ADHESIVE INC -- FA-1030 ACCELERATOR -- 8040-00-515-2246
=====================  Product Identification  =====================

Product ID:FA-1030 ACCELERATOR
MSDS Date:03/25/1993
FSC:8040
NIIN:00-515-2246
Kit Part:Y
MSDS Number: BVZGD
=== Responsible Party ===
Company Name:CLIFTON ADHESIVE INC
Address:BURGESS PLACE
City:WAYNE
State:NJ
ZIP:07474-0832
Country:US
Info Phone Num:201-694-0845
Emergency Phone Num:201-694-0845
CAGE:79833
=== Contractor Identification ===
Company Name:CLIFTON ADHESIVE INC
Address:BURGESS PL
Box:City:WAYNE
State:NJ
ZIP:07470
Country:US
Phone:201-694-0845; 973-694-0845
CAGE:79833

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYL ALCOHOL (METHANOL) (SARA III)
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: 76%
Other REC Limits:NONE SPECIFIED
OSHA PEL:S,200PPM/250STEL
ACGIH TLV:S,200PPM/250STEL; 93
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:TRIMENE BASE(ALIPHATIC AMINE)
CAS:63512-71-0

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 5628MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYES:MAY CAUSE IRRITATION.SKIN:MAY
    CAUSE IRRITATION.INGEST:MAY CAUSE GI TRACT IRRITATION.INHAL:MAY
    CAUSE RESPIRATORY IRRITATION AND CNS EFFECTS.CHRONIC:METHANOL MAY
    DAMAGE LIVER,KIDNEY,SPLEEN,EYES,LUN GS,BRAIN OR CNS.
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
    WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:NAUSEA,NARCOSIS.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING
    RESPIRATORY  AND LIVER AILMENTS MAY BE AT INCREASED RISK FROM
    EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH SOAP AND
    WATER.EYES:FLUSH WITH WATER FOR 15 MINUTES.INHAL:REMOVE TO FRESH
    AIR.GIVE OXYGEN OR ARTIFICIAL RESPIRATION IF NEEDED.INGEST:DO NOT
    INDUCE VOMITING. GET PROMPT QUALIFIED MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:54F/12C
Lower Limits:5.5
Upper Limits:36.5
Extinguishing Media:CO2, FOAM AND DRY CHEMICAL
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
    FULL PROTECTIVE EQUIPMENT.COOL FIRE EXPOSED CONTAINERS WITH WATER
    FOG.
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR,CAN TRAVEL
    DISTANCES ALONG THE GROUND,AND FLASHBACK AT THE SOURCE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION.USE PROPER
    RESPIRATORY AND PROTECTIVE EQUIPMENT.VENTILATE AREA.SOAK UP WITH A
    NON-COMBUSTIBLE INERT ABSORBANT(CLAY,SAND);PLACE IN PROPER
    CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN APPROVED SOLVENT STORAGE
    AREA. KEEP TIGHTLY CLOSED. KEEP AWAY FROM HEAT, OPEN FLAMES,
    SPARKS, HOT SURFACES AND OXIDIZING AGENTS.
Other Precautions:FOLLOW LABEL DIRECTIONS.AVOID BREATHING VAPORS.AVOID
    SKIN AND EYE CONTACT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
    ENCLOSED SPACES USE EITHER A SELF-CONTAINED BREATHING APPARATUS OR
    A NOISH/MSHA APPROVED RESPIRATOR FOR ORGANIC VAPORS,DEPENDING ON
    THE AIRBORN CONCENTRA TION.
Ventilation:LOCAL VENTILATION AT THE WORKSITE;MECHANICAL(GENERAL)
    VENTILATION TO MAINTAIN TLV/PEL.USE NON-SPARKING EQUIPMENT.
Protective Gloves:PVA GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING,AS NEEDED.PROVIDE A
    LOCAL EYE WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET
    CLOTHES.LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK
    AREA.
Supplemental Safety and Health
KEY1;F3.HMIS SPOKE TO JOAN MILLER AT CLIFTON CHEMICALS.SHE ADVISED US
    THAT THIS IS THE ACCELERATOR FOR BOTH FA-1065 AND FA-1030.

==================  Physical/Chemical Properties  ==================

HCC:F2
Boiling Pt:B.P. Text:147F,64C
Vapor Pres:97.7 @ 68F
Vapor Density:1.11
Spec Gravity:0.851
Appearance and Odor:LIQUID;AMBER;PUNGENT ALCOHOLIC ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:AVOID HEAT, OPEN FLAMES, SPARKS AND HOT
    SURFACES.
Hazardous Decomposition Products:AMMONIA AND HYDROGEN CHLORIDE

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
    LOCAL REGULATIONS.HMIS SUGGESTS RCRA CODE D001(IGNITABLE).

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.