PRATT & LAMBERT INC -- JETGLO HEAVY METAL FREE CLEAR & COLORS, MSDS28 -- 8010-00N070375
=====================  Product Identification  =====================

Product ID:JETGLO HEAVY METAL FREE CLEAR & COLORS, MSDS28
MSDS Date:03/11/1993
FSC:8010
NIIN:00N070375
MSDS Number: CBLRN
=== Responsible Party ===
Company Name:PRATT & LAMBERT INC
Box:2153
City:WICHITA
State:KS
ZIP:67201
Country:US
Info Phone Num:316-733-1361
Emergency Phone Num:716-873-6000; 800-255-3924
CAGE:PRATT
=== Contractor Identification ===
Company Name:PRATT & LAMBERT
Address:250 PETTIT AVE
Box:2153
City:BELLMORE
State:NY
ZIP:11710
Country:US
Phone:800-647-2253
CAGE:PRATT
Company Name:PRATT AND LAMBERT INC
Address:Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE
    GLYCOL METHYL ETHER ACETATE)   VP: 2 @ 20C
CAS:108-65-6
RTECS #:AI8925000
Fraction by Wt: 25%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:XYLENE (SARA 313) (CERCLA)	 VP: 5 @ 20C
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: <5%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM; 150 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ACETIC ACID, ETHYL ESTER; (ETHYL ACETATE) (CERCLA)	 VP: 73
    @ 20C
CAS:141-78-6
RTECS #:AH5425000
Fraction by Wt: 20%
OSHA PEL:400 PPM
ACGIH TLV:400 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:ETHYL ALCOHOL   VP: 44 @ 20C
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: 5%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM

Ingred Name:ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE) (CERCLA)   VP:
    10 @ 20C.
CAS:123-86-4
RTECS #:AF7350000
Fraction by Wt: 15%
OSHA PEL:150 PPM
ACGIH TLV:150 PPM; 200 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:HEXANE, 1,6-DIISOCYANATO-; (1,6 HEXANE METHYLENE
    DIISOCYANATE) (CERCLA)
CAS:822-06-0
RTECS #:MO1740000
Fraction by Wt: <1%
OSHA PEL:N/K 
ACGIH TLV:0.005 PPM
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:ISOCYANIC ACID, HEXAMETHYLENE ESTER, POLYMERS; (POLYMERIC
    HEXANETHYLENE DIISOCYANAGE)
CAS:28182-81-2
RTECS #:NQ9170000
Fraction by Wt: 15%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:TOLUENE (SARA 313) (CERCLA)   VP: 22 @ 20C
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: <5%
OSHA PEL:200 PPM
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:CYCLOHEXANONE (CERCLA)   VP: 2 @ 20C
CAS:108-94-1
RTECS #:GW1050000
Fraction by Wt: <5%
OSHA PEL:50 PPM, S
ACGIH TLV:25 PPM, S
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:DIPROPYLENE GLYCOL METHYL ETHER ACETATE
CAS:88917-22-0
Fraction by Wt: <5%
OSHA PEL:100 PPM, S
ACGIH TLV:100 PPM, S

Ingred Name:VOLATILE ORGANIC COMPOUND:5.60LB/GAL LESS H*2O & NPRS;
    672G/L LESS H*2O; 20.79LB/GAL SOLIDS; 2495G/L SOLIDS (CALCULATED)
RTECS #:9999999VO
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT: TO XYLENE MAY CAUSE INJURY TO LIVER, KIDNEYS &
    BLOOD. RPTD OVEREXP TO TOLUENE MAY CAUSE LIVER DMG. RPTD (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12: OVEREXP TO DIISOCYANATES MAY RSLT IN RESP SENSIT IN
    SOME INDIVIDUALS. RESP SENSITIVITY RSLTS IN ASTHMA- (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13: LIKE SYMPS ON SUBSEQUENT EXPOS AT CONCS EVEN BELOW
    TLV. RPTS HAVE ASSOC PRLNGD & RPTD OCCUP OVEREXP TO (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14: SOLVS W/PERM BRAIN & NERVS SYS DMG. INTENTIONAL
    MISUSE BY DELIB CONC & INHAL CONTENTS MAY BE HARMFUL OR (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15: OR FATAL. TOLUENE HAS BEEN FOUND TO CAUSE KIDNEY,
    LUNG & SPLEEN DMG IN LAB ANIMALS.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC: MD. NOTES TO MD:ANY TREATMENT REQD FOR
    OVEREXP SHOULD BE DIRECTED AT CTL OF SYMPS & CLINICAL CNDTNS.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC: METAL CNTNRS FOR RECOVERY/DISP/REMOVE W/INERT
    ABSORB. USE ONLY NON-SPKG TOOLS. PLACE ABSORB DIKING (ING 19)
RTECS #:9999999ZZ

Ingred Name:ING 18:MATLS IN COVERED METAL CNTNRS FOR DISP. PVNT CONTAM
    OF SEWERS, STREAMS & GROUNDWATER W/SPILLED MATL/USED ABSORB.
RTECS #:9999999ZZ

Ingred Name:OTHER PRECS: GROUNDED & BONDED TO RECEIVING CNTNR. DO NOT
    WELD, BRAZE OR CUT AN EMPTY CNTNR. NEVER USE PRESS TO (ING 21)
RTECS #:9999999ZZ

Ingred Name:ING 20: EMPTY. DRUM IS NOT A PRESSURE VESSEL.
RTECS #:9999999ZZ

Ingred Name:RESP PROT: RESP FOR WHOLE TIME WHILE MIXING, SPRAYING &
    UNTIL VAP & MIST ARE GONE. FOLLOW RESP MFR'S DIRECTIONS FOR USE.
RTECS #:9999999ZZ

Ingred Name:VENT: PERMISSIBLE EXPOS LIMITS WHICH MAY BE LISTED. REFER
    TO INDUS VENT - A MANUAL FOR RECOM PRACTICE - ACGIH.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGEST:MAY BE FATAL IF SWALLOWED. CAN
    CAUSE GI IRRIT, NAUS & VOMIT. ASPIR INTO LUNG MAY CAUSE POSS FATAL
    CHEM PNEUM. INHAL:WARNING. VAP & SPRAY MIST HARMFUL. OVEREXP MAY
    CAUSE LUNG DMG & IRRIT & ALLER GIC RESP RXN. EFTS MAY BE PERM. MAY
    CAUSE RESP SENSIT, NOSE/THROAT IRRIT. HIGH CONCS MAY CAUSE ACUTE
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CNS DEPRESS CHARACT BY HDCH, DIZZ,
    NAUS & CONFUSN. EYE:MAY CAUSE SEV IRRIT. SKIN:LIQ MAY BE ABSORBED
    IN HARMFUL AMTS. PRIMARY SKIN IRRITANT. MAY CAUSE SENSIT (ALLERGIC
    RXN); SEV IRRIT. CHRONI C: TOLUENE APPEARS ON THE NAVY LIST OF
    OCCUP CHEM REPRO HAZS. SEEK CONSULTATION FROM APPROP HLTH
    PROFESSIONALS (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:DO NOT INDUCE VOMIT. CALL POS CTL CTR, HOSPITAL EMER
    ROOM/MD IMMED. INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG HAS
    STOPPED, GIVE ARTF RESP. KEEP WARM & QUIET. GET MED ATTN IMMED.
    EYE:FLUSH W/LG  AMTS OF WATER, LIFTING UPPER & LOWER LIDS OCCAS.
    CONTINUE FOR AT LEAST 15 MIN. GET MED ATTN. SKIN:IMMED FLUSH
    CONTAMD AREA W/LG AMTS OF WATER. REMOVE CONTAMD CLTHG AS WATER IS
    APPLIED. CONSULT(ING 17)

=====================  Fire Fighting Measures  =====================

Flash Point:24.0F,-4.4C
Extinguishing Media:NFPA CLASS B FIRE EXTINGS (CO*2, ALL PURPOSE DRY
    CHEM/ALCOHOL FOAM) DESIGNED TO EXTING FLAM LIQ FIRES. POLYMER
    (SUPDAT)
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
    WATER MAY BE INEFTIVE BUT MAY BE USED TO COOL EXPOS CNTNRS TO PVNT
    PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO(SUPDAT)
Unusual Fire/Explosion Hazard:DURING EMER CONDITIONS, OVEREXPOXURE TO
    DECOMPOSITION PRODUCTS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED
    APPARENT. OBTAIN MEDICAL ATTENTION. WARNING:FLAMMABLE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE NIOSH/MSHA APPRVD TC19C, AIR-SUPPLIED
    BRTHG APPARATUS. KEEP SPECTATORS AWAY. ELIM ALL IGNIT SOURCES
    (FLAMES, HOT SURFS & SOURCES OF ELEC/STATIC/FRICTIONAL SPKS). DIKE
    & CNTN SPILL W/INERT MATL (EG  SAND, EARTH). TRANSFER LIQS TO
    COVERED(ING 18)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE >115F(46C). STORE LG QTYS
    IN COMPLIANCE W/OSHA 29CFR 1910.106. DO NOT TAKE INTERNALLY. CLOSE
    CNTNR AFTER EACH USE.
Other Precautions:PROD SHOULD NOT BE USED BY PERS WHO HAVE HAD CHRONIC
    (LONG TERM) BRTHG PROBS/RXNS TO ISOCYANATES. KEEP AWAY FROM HEAT,
    SPKS OR FLAME. USE ONLY W/ADEQ VENT. EMPTY CNTNRS MUST NOT BE
    WASHED & REUSED FOR  ANY PURPOSE. CNTNRS SHOULD BE (ING 20)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WEAR APPROP NIOSH/MSHA APPRVD PROPERLY FITTED
    POS PRESS AIR SUPPLIED RESP (TC 19C) WHILE EXPOS. IF NOT AVAIL, USE
    NIOSH/MSHA APPRVD VAP PARTICULATE, (PAINT SPRAY) RESP THAT RESP MFR
    REC AS EFTIVE FOR  ISOCYANATE VAPS & MISTS. WEAR (ING 22)
Ventilation:PROVIDE LOC EXHST VENT IN SUFFICIENT VOL & PATTERN SO AS TO
    MAINTAIN EXPOS BELOW NUISANCE DUST LIMS & (ING 23)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . AS
    REQUIRED TO PREVENT SKIN CONTACT.
Work Hygienic Practices:DO NOT BREATHE VAPOR SPRAY/MIST. DO NOT GET IN
    EYES, ON SKIN OR CLOTHING. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EXTING MEDIA:FOAM IS PREF FOR LG FIRES. FIRE FIGHT PROC:WHEN EXPOS TO
    EXTREME HEAT. IF WATER IS USED, FOG NOZZS PREF. HAZ DECOMP
    PRODS:RXN OF ISOCYANATES W/WATER MAY PRDCE CO*2 GAS WHICH MAY RSLT
    IN C NTNR PRESSURIZATION. EFTS OF OVEREXP:CONCERNING LATEST HAZ
    LIST INFO & SAFE HNDLG & EXPOS INFO . OVEREXP (ING 12)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>167F,>75C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.0
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:73

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS. ACETYL CHLORIDE. OXIDIZING
    MATERIALS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT (>115F, >46C) AND
    SOURCES OF IGNITION.
Hazardous Decomposition Products:BURNING, INCL WHEN HEATED BY WELD/CUT,
    WILL PRDCE SMOKE, CO & CO*2. IN ADDN OXIDES OF NITROGEN MAY BE
    GENERATED.(SUPDAT)

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL REGS. THIS
    PRODUCT, IF DISCARDED DIRECTLY, WOULD BE CLASSIFIED A HAZARDOUS
    WASTE BASED ON ITS IGNITABILITY CHARACTERISTIC, IE HAS A FLASH
    POINT OF 140F (60C) OR LE SS. PROPER RCRA CLASSIFICATION WOULD
    BED001.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.