adverstisement



MCGEE INDUSTRIES INC -- MCLUBE 1700 AEROSOL -- 8030-00N045307
=====================  Product Identification  =====================

Product ID:MCLUBE 1700 AEROSOL
MSDS Date:05/01/1990
FSC:8030
NIIN:00N045307
MSDS Number: BTXCQ
=== Responsible Party ===
Company Name:MCGEE INDUSTRIES INC
Address:9 CROZERVILLE ROAD
City:ASTON
State:PA
ZIP:19014
Country:US
Emergency Phone Num:800-262-5823;800-424-9300(CHEMTREC)
CAGE:FO077
=== Contractor Identification ===
Company Name:MCGEE IND INC
Address:9 CROZERVILLE RD
Box:City:ASTON
State:PA
ZIP:19014
Country:US
Phone:800-262-5823
CAGE:04672
Company Name:MCGEE INDUSTRIES/ASTON, PA 19014
CAGE:FO077

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHANE, 1,1,1-TRICHLORO-; (METHYL CHLOROFORM)  (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 85-90%
OSHA PEL:350 PPM;450 STEL
ACGIH TLV:350 PPM;450 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:ISOPROPYL ALCOHOL  (SARA III)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 1%
OSHA PEL:400 PPM;500 STEL
ACGIH TLV:400 PPM;500 STEL

Ingred Name:ETHANE 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;
    (1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE) (FREON 113)  (SARA III)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 3-6%
OSHA PEL:1000 PPM;1250 STEL
ACGIH TLV:1000 PPM;1250 STEL
Ozone Depleting Chemical:1

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 4-6%
OSHA PEL:10000 PPM;30000 STEL
ACGIH TLV:5000 PPM;30000 STEL

Ingred Name:SUPP DATA: NO SMOKING IN AREA OF USE. DO NOT USE IN GEN
    VICIN OF ARC WELDING, OPEN FLAMES OR HOT SURFS. HEAT (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5: &/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL
    &/OR PHOSGENE .
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL:PRLNGD BRTHG OF HIGH CONC OF VAP
    MAY CAUSE LT HEAD, DIZZ & LOSS OF BALANCE & MAY LEAD TO CARDIAC
    IRREGS, UNCON OR EVEN DEATH. THESE CNDTNS WOULD NOT BE EXPERIENCED
    IN NORMAL USE BUT ONLY BY SPRA YING IN A CONFINED AREA FOR A
    PROLONGEDPERIOD OR THROUGH DELIBERATE ABUSE. SKIN/EYE: MILD
    IRRITATION. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INGEST: LOW ORAL TOXICITY.
    CHLOROCARBON MATLS HAVE PRODUCED SENSIT OF THE MYOCARDIUM TO
    EPINEPHRINE IN LAB ANIMALS AND COULD HAVE SIMILAR EFTS IN HUMANS.
    ADRENOMIMETICS (E.G., EPINEPHRINE) MA Y BE CONTRAINDICATED EXCEPT
    FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
    TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER IMMEDIATELY FOR AT LEAST 15 MIN. SKIN:
    WASH OFF IN FLOWING WATER. INHAL: REMOVE TO FRESH AIR; IF NOT
    BREATHING, HAVE QUALIFIED PERSON GIVE MOUTH-TO-MOUTH RESUSCITATION;
    IF BREAT HING DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. INGEST: DO
    NOT INDUCE VOMITING. CALL A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Lower Limits:7.5%
Upper Limits:15%
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:WATER FOG MAY BE USED TO COOL CLOSED CNTNR TO
    PVNT BUILDUP WHEN EXPOSED TO EXTREME HEAT. WEAR NIOSH/MSHA APPRVD
    PRESS DEMAND SCBA & FULL PROT EQUIPMENT .
Unusual Fire/Explosion Hazard:CONTAINERS MAY EXPLODE WHEN EXPOSED TO
    EXTREME HEAT. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND
    PHOSGENE .

==================  Accidental Release Measures  ==================

Spill Release Procedures:SOAK UP WITH INERT ABSORBENT SUCH AS SAND,
    EARTH OR VERMICULITE AND PUT IN CLOSED CONTAINER FOR PROMPT
    DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTENTS UNDER PRESSURE. DO NOT
    PUNCTURE OR INCINERATE CAN. DO NOT PLACE CAN ON OR NEAR HEATED
    SURFACES. PROVIDE ADEQ VENT WHEN SPRAYING.
Other Precautions:AVOID PROLONGED &/OR DELIBERATE BREATHING OF SPRAY
    MIST. DO NOT SMOKE WHILE USING NOR CONTAMINATE TOBACCO PRODUCTS.
    HEATING SOLID ACTIVE INGREDIENTS ABOVE 500F MAY CAUSE FORMATION OF
    POTENTIALLY TOX S UBSTANCES. TRICHLOROETHANE (SUPP DATA)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN ABSENCE OF ENVIRONMENTAL CONTROL, NIOSH/MSHA
    APPROVED ORGANIC VAPOR-TYPE RESPIRATOR REQUIRED.
Ventilation:CONTROL VAPOR TO STANDARD - OSHA STANDARD 350 PPM.
Protective Gloves:IMPERMEABLE GLOVES RECOMMENDED.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
APPEAR & ODOR:SPRAYING & DRYING LEAVES A DRY, WHITE RESIDUE. PHYSICAL
    DATA APPLY TO CONC (LESS PROPELLANT). OTHER PREC: &
    TRICHLOROTRIFLUOROETHANE ARE TOX CHEMS SUBJECT TO THE REPORTING
    REQUIREMENTS O F SECT 313 OF TITLE III OF THE SUPERFUND AMENDMENTS
    & REAUTHORIZATION ACT (SARA) OF 1986 & 40 CFR PART 372. (ING 5)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>118F,>48C
Vapor Pres:100 @ 20C
Vapor Density:4.55
Spec Gravity:1.3
Evaporation Rate & Reference:2.5 (ETHER=1)
Solubility in Water:0.07 (% BY WT)
Appearance and Odor:WHITE, TRANSLUCENT LIQUID, SLIGHT ETHEREAL ODOR.
    AEROSOL MIST AFTER (SUPP DATA)
Percent Volatiles by Volume:93-99

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
REACTIVE METALS, ESPECIALLY POWDERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, HYDROGEN FLUORIDE,
    VERY SMALL AMTS OF PHOSGENE & CHLORINE & POSSIBLY OTHER TOX
    FLUORINE CMPNDS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:SEND TO APPROVED LANDFILL IN COMPLIANCE WITH
    LOCAL, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.