CHEVRON USA PRODUCTS CO -- WAY OIL VISTAC ISO 220, CPS232512 -- 9150-00N085303
=====================  Product Identification  =====================

Product ID:WAY OIL VISTAC ISO 220, CPS232512
MSDS Date:01/03/1996
FSC:9150
NIIN:00N085303
MSDS Number: CHCNC
=== Responsible Party ===
Company Name:CHEVRON USA PRODUCTS CO
Address:575 MARKET ST
City:SAN FRANCISCO
State:CA
ZIP:94105-2856
Country:US
Info Phone Num:800-582-3835
Emergency Phone Num:800-231-0623;800-424-9300(CHEMTREC)
CAGE:81230
=== Contractor Identification ===
Company Name:CHEVRON PRODUCTS COMPANY LUBRICANTS AND SPECIALTY PRODUCTS
Address:6001 BOLLINGER CANYON RD
Box:City:SAN RAMON
State:CA
ZIP:94583
Country:US
Phone:800-414-6737 / 800-582-3835
CAGE:81230
Company Name:CHEVRON USA INC DBA CHEVRON PRODUCTS CO
Address:575 LENNON LN
Box:City:WALNUT CREEK
State:CA
ZIP:94598
Country:US
Phone:510-977-7283
CAGE:04BH0

=============  Composition/Information on Ingredients  =============

Ingred Name:LUBRICATING BASE OIL CONTAINING ONE OR MORE OF INGS
    2,3,4,5,6, & 7
Fraction by Wt: 98%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT REFINED
    (SEVERE), HEAVY NAPHTHENIC
CAS:64741-96-4
RTECS #:PY8040001
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
    HEAVY NAPHTHENIC
CAS:64742-52-5
RTECS #:PY8035001
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
    HEAVY NAPHTHENIC
CAS:64742-54-7
RTECS #:PY8035501
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
    LIGHT NAPHTHENIC
CAS:64742-53-6
RTECS #:PY8036000
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED HEAVY
    PARAFFINIC (SEVERE SOLVENT-REFINING AND/OR HYDROTREATMENT).
CAS:64742-65-0
RTECS #:PY8038501
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ADDITIVES
Fraction by Wt: 2%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT: RESP IRRIT. THIS HAZARD EVALUATION IS BASED ON DATA
    FROM SIMILAR MATLS. TOX INFO: EYE/SKIN: NO PROD TOX (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8: DATA AVAIL. HAZARD EVALUTION WAS BASED ON DATA FROM
    SIMILAR MATLS. ACUTE INGEST & INHAL: NO PROD TOX (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9: DATA IS AVAIL. HAZARD EVALUATION WAS BASED ON DATA
    FROM SIMILAR MATLS. ADDNL TOX INFO: PROD CONTAINS (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10: PETROLEUM BASE OILS WHICH MAY BE REFINED BY VARIOUS
    PROCESSES INCL SEV SOLV EXTRACTION, SEVERE (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11: HYDROCRACKING/SEV HYDROTREATING. NONE OF OILS REQ
    CANCER WARNING UNDER OSHA HAZARD COMMUNICATION STD (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12: (29 CFR 1910.12). THESE OILS HAVE NOT BEEN LISTED
    IN NTP NOR HAVE THEY BEEN CLASSIFIED BY IARC AS; (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13: CARCINOGENIC TO HUMANS (GROUP 1), PROBABLY CARCIN
    TO HUMANS (GROUP 2A), OR POSSIBLY CARCIN TO HUMANS (GROUP 2B).
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC: SEE DOCTOR IF DISCOMFORT OR IRRITATION
    CONTINUES.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC: PUMPING. WHERE FEASIBLE & APPROP, REMOVE
    CONTAMD SOIL. FOLLOW PRESCRIBED PROCEDURES FOR REPORTING (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16: AND RESPONDING TO LARGER RELEASES.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: SUBSTANCE IS NOT EXPECTED
    TO CAUSE PRLNGD/SIGNIFICANT EYE IRRIT. THIS HAZARD EVALUATION IS
    BASED ON DATA FROM SIMILAR MATLS. SKIN: SUBSTANCE IS NOT EXPECTED
    TO CAUSE PLNGD/SIGNIFICANT SKIN  IRRIT. THIS HAZARD EVALUATION IS
    BASEDON DATA FROM SIMILAR MATLS. SYSTEMIC TOX OF SUBSTANCE HAS
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: NOT BEEN DETERM. HOWEVER, IT SHOULD
    BE PRACTICALLY NON-TOXIC TO INTERNAL ORGANS IF IT GETS ON SKIN.
    THIS HAZARD EVALUATION IS BASED ON DATA FROM SIMILAR MATS. INGEST:
    SYSTEMIC TO TOX OF SUBS TANCE HAS NOT BEEN DETERM. HOWEVER, IT
    SHOULD BE PRACTICALLY NON-TOXIC TO INTERNAL ORGANS IF SWALLOWED.
    THIS (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE: FLUSH W/FRESH WATER FOR @ LST 15 MINS. REMOVE CONTACT
    LENSES IF WORN. SKIN: WASH THOROUGHLY W/SOAP & WATER. REMOVE & WASH
    CONTAMD CLTHG. INGEST: IF SWALLOWED, GIVE WATER/MILK TO DRINK &
    TELEPHONE  MED ADVICE. CONSULT MED PERSONNEL BEFORE INDUCING VOMIT.
    IF MED ADVICE CANNOT BE OBTAINED, THEN TAKE PERSON & PROD CNTNR TO
    NEAREST MED EMER TREATMENT CTR/HOSPITAL. INHAL: MOVE TO FRESH AIR.
    (ING 15)

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:374F,190C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM AND WATER FOG.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NORMAL COMBUSTION FORMS CARBON DIOXIDE
    AND WATER VAPOR; INCOMPLETE COMBUSTION CAN PRODUCE CARBON MONOXIDE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP SOURCE OF LEAK/RELEASE. CLEAN UP RELEASES
    AS SOON AS POSS, OBSERVING PRECS IN EXPOS CTLS/PERSON PROT. CNTN
    LIQ TO PVNT FURTHER CONTAM OF SOIL, SURF WATER/GROUNDWATER. CLEAN
    UP SM SPILLS USING APP ROP TECHNIQUES SUCH AS SORBENT MATLS OR(ING
    16)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:READ AND OBSERVE ALL PRECAUTIONS ON
    PRODUCT LABEL. DO NOT WELD, HEAT OR DRILL CONTAINERS. SKIN CONT CAN
    BE MINIMIZED BY WEARING PROTECTIVE CLOTHING.
Other Precautions:RESIDUE MAY IGNITE W/EXPLOSIVE VIOLENCE IF HEATED
    SUFFICIENTLY. CAUTION! DO NOT USE PRESS TO EMPTY DRUM OR DRUM MAY
    RUPTURE WITH EXPLOSIVE FORCE. AVOID PRLNGD/FREQUENTLY RPTD SKIN
    CONT W/THIS MATL.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NO SPECIAL RESPIRATORY PROTECTION IS NORMALLY
    REQUIRED. HOWEVER, IF OPERATING CONDITIONS CREATE AIRBORNE
    CONCENTRATIONS WHICH EXCEED THE RECOMMENDED EXPOSURE STANDARDS, THE
    USE OF NIOSH APPROVED RESPI RATOR IS REQUIRED.
Ventilation:NO SPEC VENT IS USUALLY NEC. HOWEVER, IF OPERATING CNDTNS
    CREATE HIGH AIRBORNE CONCS OF MATL, SPEC VENT MAY BE NEEDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O: SOL IN HYDROCARBON SOLVS; INSOL IN WATER. EFTS OF OVEREXP:
    HAZARD EVALUATION IS BASED ON DATA FROM SIMILAR MATL. INHAL: SYSTEM
    TOX OF SUBSTANCE HAS NOT BEEN DETERM. HOWEVER, IT SHOULD BE 
    PRACTICALLY NON-TOXIC TO INTERNAL ORGANS IF INHALED. PRLNGD/RPTD
    BRTHG OF PETRO OIL MIST CAN CAUSE (ING 8)

==================  Physical/Chemical Properties  ==================

Spec Gravity:0.91
Solubility in Water:SUPP DATA
Appearance and Odor:DARK AMBER LIQUID.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
MAY REACT WITH STRONG OXIDIZING AGENTS, SUCH AS CHLORATES, NITRATES,
    PEROXIDES, ETC.
Stability Condition to Avoid:NO DATA AVAILABLE.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:OIL COLLECTION SERVICES ARE AVAIL FOR USED OIL
    RECYCLING/DISP. PLACE CONTAMD MATLS IN CNTNRS & DISPOSE OF IN
    MANNER CONSISTENT W/APPLIC FED, STATE & LOCAL REGS. CONT SALES
    REPRESENTATIVE/LOC ENVIRONME NTAL/HLTH AUTH FOR APPRVD
    DISP/RECYCLING METHODS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.