GENERAL ELECTRIC CO., SILICONE PRODUCT DIV. -- RTV 162 POLYDIMETHYLSILOXANE SEALANT -- 8040-01-227-6153
=====================  Product Identification  =====================

Product ID:RTV 162 POLYDIMETHYLSILOXANE SEALANT
MSDS Date:10/03/1996
FSC:8040
NIIN:01-227-6153
Status Code:A
MSDS Number: CJHJZ
=== Responsible Party ===
Company Name:GENERAL ELECTRIC CO., SILICONE PRODUCT DIV.
Address:260 HUDSON RIVER ROAD
City:WATERFORD
State:NY
ZIP:12188
Country:US
Info Phone Num:518-237-3330
Emergency Phone Num:518-237-3330
Preparer's Name:C E HANNIGAN
CAGE:01139
=== Contractor Identification ===
Company Name:GENERAL ELECTRIC CO, SILICONE PRODUCTS BUSINESS DEPT
Address:260 HUDSON RIVER RD
Box:City:WATERFORD
State:NY
ZIP:12188
Country:US
Phone:518-237-3330/800-332-3390
CAGE:01139

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYLTRIMETHOXYSILANE. LD50 RAT ORAL 12500 MG/KG. ACUTE
    DEERMAL RABBIT LD50 >10,000 MG/KG.
CAS:1185-55-3
RTECS #:VV4650000
Fraction by Wt: 1-5%
OSHA PEL:200 PPM(R)TWA
ACGIH TLV:200 PPM(R)TWA

Ingred Name:DIMETHYL POLYSILOXANE SILANOL/ST. ACUTE ORAL LD50 RAT 
    >40,000 MG/KG. LC50 RAT INHALATION >535 MG/L.
CAS:70131-67-8
Fraction by Wt: 60-80%
Other REC Limits:NOT KNOWN
OSHA PEL:NOT KNOWN
ACGIH TLV:NOT KNOWN

Ingred Name:DIMETHYLPOLYSILOXANES. ACUTE ORAL LD50 >40,000 MG/KG. ACUTE
    LC50 INHALATION >535 MG/L RAT. OTHER: NONIRRITATING TO SKIN (RBT).
CAS:63148-62-9
RTECS #:JT6484500
Fraction by Wt: 5-10%
Other REC Limits:NOT KNOWN
OSHA PEL:NOT KNOWN
ACGIH TLV:NOT KNOWN

Ingred Name:D4&HMDZ TREATED SILICON DIOXIDE ACUTE ORAL LD50: 3160 RAT
    (EST).
CAS:68937-51-9
Fraction by Wt: 10-30%
OSHA PEL:15 MG/M3
ACGIH TLV:10 MG/M3 TWA

Ingred Name:1,3,5-TRIS(TRIMETHOXYSILYLPROPYL)-ISOCYANURATE
CAS:26115-70-8
Fraction by Wt: 1-5%

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE INDIVIDUAL INGREDIENTS FOR LD50
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT CONTAINS
    METHYLPOLYSILOXANES WHICH CAN GENERATE FORMALDEHYDE AT
    APPROXIMATELY 300 F(150'C) AND ABOVE, IN ATMOSPHERES WHICH CONTAIN
    OXYGEN. FORMALDEHYDE IS A SKIN & RESPIRATORY SENSITIZER,  EYE AND
    THROAT IRRITANT, ACUTE TOXICANT, & POTENTIAL CANCER HAZARD. AN MSDS
    FOR FORMALDHYDE IS AVAILABLE FROM G E SILICONES. PRODUCT RELEASES
    METHANOL (1-3%) BY WEIGHT) DURING CURE PROCESS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: MAY BE HARMFUL IF SWALLOWED. SKIN:
    UNCURED PRODUCT CONTACT IRRITATES LIPS, GUMS, & TONGUE. MAY CAUSE
    MILD SKIN IRRITATION. INHALATION: MILD RESPIRATORY IRRITATION.
    APPLIES ONLY IN UNCURED S TATE. EYES:UNCURED PRODUCT CONTACT
    IRRITATES EYES.
Medical Cond Aggravated by Exposure:NONE KNOWN

=======================  First Aid Measures  =======================

First Aid:EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
    MIN,GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN:REMOVE WITH
    COMPLETELY W/DRY CLOTH OR PAPER TOWEL BEFORE WASHING WITH DETERGENT
    AND W ATER. INGESTION:DO NOT INDUCE VOMITING. SLOWLY DILUTE WITH
    1-2 GLASSES OF WATER OR MILK.GET MEDICAL ATTENTION. NEVER GIVE
    ANYTHING TO UNCONSCIOUS PERSON BY MOUTH. INHALATION:MOVE PERSON TO
    FRESH AIR.

=====================  Fire Fighting Measures  =====================

Lower Limits:NOT KNOWN
Upper Limits:NOT KNOWN
Extinguishing Media:ALL STANDARD FIREFIGHTING MEDIA.
Fire Fighting Procedures:NONE KNOWN.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WIPE, SCRAPE OR SOAK UP IN INERT MATERIAL AND
    PUT IN CONTAINER FOR DISPOSAL. WASH WALKING SURFACES WITH DETERGENT
    AND WATER TO REDUCE SLIPPING HAZARD. WEAR PROPER PROTECTIVE
    EQUIPMENT.
Neutralizing Agent:NOT KNOWN

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID CONTACT W/ SKIN & EYES. USE ONLY
    IN WELL VENTILATED AREA. PRODUCT RELEASES METHANOL DURING
    APPLICATION & CURING (METHANOL TLV=200 PPM). UNCURED PRODUCT
    CONTACT IRRITATES EYES.
Other Precautions:AVOID CONTACT WITH SKIN & EYES. REMOVE CONTACT LENSES
    BEFORE USING SEALANT. DO NOT HANDLE LENSES UNTIL
    FINGERTIPS,NAILS,CUTICLES THOROUGHLY CLEANED. RESIDUE MAY REMAIN ON
    FINGERS FOR SEVERAL DAYS, TRA NSFER TO LENSES & CAUSE SEVERE EYE
    IRRITATION.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE IN WELL VENTILATED AREA.
Ventilation:USE ONLY IN WELL VENTILATED AREA.
Protective Gloves:CLOTH GLOVES
Eye Protection:CHEMICAL SAFETY GOGGLES .
Other Protective Equipment:EYEWASH STATIONS.
Supplemental Safety and Health
PRODUCT VOC:  <44 G/L EXCLUDING WATER & EXEMPTS.  PRODUCT RELEASES
    METHANOL DURING APPLICATION AND CURING (METHANOL TLV=200 PPM).

==================  Physical/Chemical Properties  ==================

Decomp Temp:Decomp Text:NOT KNOWN
Vapor Pres:NEGLIGIBLE
Vapor Density:NEGLIGIBLE
Spec Gravity:1.085 (WATER=1)
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE@20C
Appearance and Odor:WHITE SOLID, SWEET ODOR.
Percent Volatiles by Volume:<4

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:CARBON MONOXIDE,CARBON DIOXIDE,SILICON
    DIOXIDE,METHANOL AND FORMALDEHYDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE W/
    FEDERAL/STATE/LOCAL REGULATIONS. BURY IN LICENSED LANDFILL OR BURN
    IN APPROVED INCINERATOR ACCORDING TO FED,STATE, LOCAL REGULATIONS.

=====================  Regulatory Information  =====================

Federal Regulatory Information:WHMIS HAZARD CLASS: D2B TOXIC MATERIALS

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.