XEROX CORPORATION -- 113R279,DOCUMENT CENTRE 220/230/332/340CD/ST,(SUPDAT) -- -
=====================  Product Identification  =====================

Product ID:113R279,DOCUMENT CENTRE 220/230/332/340CD/ST,(SUPDAT)
MSDS Date:04/20/1999
FSC:NIIN:Submitter:N EN
Status Code:A
MSDS Number: CKJXW
=== Responsible Party ===
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
City:ROCHESTER
State:NY
ZIP:14644
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177
Resp. Party Other MSDS Num.:A-0600
Chemtrec Ind/Phone:(800)424-9300
CAGE:26921
=== Contractor Identification ===
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921

=============  Composition/Information on Ingredients  =============

Ingred Name:IRON ORES, MAGNETITE; (IRON OXIDE)
CAS:1309-38-2
RTECS #:OM4800000
Minumum % Wt:45.
Maxumum % Wt:50.

Ingred Name:BUTYL ACRYLATE-STYRENE POLYMER; (STYRENE/ACRYLATE
    COPOLYMER)
CAS:25767-47-9
Minumum % Wt:40.
Maxumum % Wt:50.

Ingred Name:1-PROPENE POLYMER; (POLYOLEFIN)
CAS:9003-07-0
RTECS #:UD1842000
Minumum % Wt:1.
Maxumum % Wt:10.

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50: (ORAL, RAT) >5 G/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
    MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
    ADDITIONAL INFORMATION: NONE. ALSO, SEE TOXICOLOGICAL INFO.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
    PRODUCT LITERATURE.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH
    WITH SOAP AND WATER. INHALATION: REMOVE FROM EXPOSURE. INGESTION:
    DILUTE STOMACH CONTENTS WITH SEVERAL GLASSES OF MILK OR WATER.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER, DRY CHEMICAL, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:TONER IS COMBUSTIBLE POWDER. LIKE MOST
    ORGANIC MATERIALS IN POWDER FORM, IT CAN FORM EXPLOSIVE MIXTURES
    WHEN DISPERSED IN AIR. NFPA 704: HEALTH - 0; FIRE - 3; REACTIVITY -
    0.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP UP OR VACUUM SPILLED TONER & CAREFULLY
    TRANSFER INTO SEALABLE WASTE CNTNR. SWEEP SLOWLY TO MINIMIZE
    GENERATION OF DUST DURING CLEAN UP. IF VACUUM IS USED, THE MOTOR
    MUST BE RATED AS DUST TIGHT.  A CONDUCTIVE HOSE BONDED TO MACHINE
    SHOULD BE USED TO REDUCE STATIC BUILDUP. RESIDUE CAN BE REMOVED
    W/SOAP & WATER. GARMENTS MAY BE WASHED OR DRY-CLEANED AFTER REMOVAL
    OF LOOSE TONER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE. AVOID PROLONGED INHALATION OF
    EXCESSIVE DUST.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . NONE REQUIRED WHEN USED AS INTENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH & DELUGE SHOWER MTG ANSI DESIGN
    CRITERIA . FOR USE OTHER THAN NORMAL CUSTOMER - OPERATING
    PROCEDURES (SUCH AS IN BULK TONER PROCESSING FACILITIES), GOGGLES
    AND RESPIRATORS MAY (SUPDAT)
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: DOCUPRINT N24/N32/N40 TONER CARTRIDGE. OTHER
    PROT EQUIP: BE REQUIRED. FOR MORE INFORMATION, CONTACT XEROX.
    PHYSICAL DATA: SOFTENING RANGE: 43.3-60C(110-140F).

==================  Physical/Chemical Properties  ==================

Spec Gravity:1 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK POWDER; FAINT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC.
    AVOID BREATHING SMOKE.

===================  Toxicological Information	===================

Toxicological Information:THIS MATL HAS BEEN EVALUATED BY XEROX CORP.
    THE TOXICITY DATA NOTED BELOW IS BASED ON TEST RSLTS OF SIMILAR
    TONERS. ORAL LD50: (RATS) >5 G/KG (PRACTICALLY NON-TOXIC). DERMAL
    LD50: >5 G/KG (RABBITS) PR ACTICALLY NON-TOXIC. INHAL LC50: >5 MG/L
    (RATS, 4 HR EXPOS) PRACTICALLY NON-TOXIC. >20 MG/L (RATS,
    CALUCLATED 1 HR EXPOS) NON-POISONOUS, DOT. EYE IRRIT:
    NON-IRRITATING. SKIN SENSITIZER: NOT SENSITIZER . SKIN IRRIT: NOT
    IRRITANT. HUMAN PATCH: NON-IRRIT, NON-SENSITIZING. MUTAGENICITY: NO
    MUTAGENICITY DETECTED IN AMES ASSAY. CARCINS: NONE PRESENT. 
    AQUATIC LC50: NOT TESTED. TLV: 10 MG/M3 (TDUST). PEL:  15 MG/M3
    (TDUST); (OTHER INFO)

=====================  Ecological Information  =====================

Ecological:N/P. OTHER INFO: IN THE LUNGS FOR A PRLNGD PERIOD. THIS
    STUDY WAS CONDUCTED USING A SPECIAL TEST TONER TO COMPLY W/EPA
    TESTING PROTOCOL. TEST TONER WAS TEN TIMES MORE RESPIRABLE THAN
    COMMERCIALLY AVAI L XEROX TONER & WOULD NOT BE FUNCTIONALLY
    SUITABLE FOR XEROX EQUIP.

====================  Disposal Considerations  ====================

Waste Disposal Methods:THIS MATERIAL IS NOT A HAZARDOUS WASTE ACCORDING
    TO FEDERAL REGULATION 40 CFR 261 WHEN DISPOSED. STATE AND LOCAL
    REQUIREMENTS, HOWEVER MAY BE MORE RESTRICTIVE. CONSULT WITH THE
    APPROPRIATE FEDERAL, ST ATE AND LOCAL WASTE DISPOSAL AUTHORITIES
    FOR ADDITIONAL INFORMATION. INCINERATE ONLY IN A CLOSED CON TAINER.

===================  MSDS Transport Information  ===================

Transport Information:DOT PROPER SHIPPING NAME: NA (NOT REGULATED). ID
    NUMBER: N/A. HAZARD CLASSIFICATION: N/A. PACKING GROUP: N/A.

=====================  Regulatory Information  =====================

Federal Regulatory Information:WHMIS STATUS: THIS IS NOT A WHMIS
    CONTROLLED PRODUCT.
State Regulatory Information:

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.